| Supply Voltage B+ | 11.8 | v | |||||||||
| B+ voltage - Plate Voltage = Voltage drop across Rp | |||||||||||
| Resistor Value Rp | 46 | k | Drop= | 5.9 | volts | ||||||
| Grid R-Value for next stage Rg | 1000 | k | |||||||||
| Plate Voltage | 5.9 | v | (Rp*Rg) / (Rp+Rg) = Adjusted plate load resistance | ||||||||
| 43.97706[1] | |||||||||||
| Internal Plate Resistance Rpg | 12.5 | k | |||||||||
| Voltage drop / Plate resistor value = Current across plate resistor | |||||||||||
| Grid Voltage | -0.5 | v | Current= | 0.1283 | |||||||
| Internal Grid to Cathode Rgk | 0.5 | k | |||||||||
| CathodeVoltage | 0.2 | v | -3.89831 | Suggested Rk value | |||||||
| 1.4 | k= Actual Rk value | ||||||||||